Power Distribution Hub Status LED Patterns
These led patterns only apply to firmware version 21.1.7 and later
General Status LED
Blue Solid
Anytime
Device on but no communication established
Green Solid
Anytime
Main Communication with roboRIO established
Magenta Blinking
Anytime
Keep Alive Timeout
Solid Cyan
Anytime
Secondary Heartbeat (Connected to REV Hardware Client)
Orange/Blue Blinking
Anytime
Low Battery
Orange/Yellow Blinking
Anytime
CAN Fault
Orange/Cyan Blinking
Anytime
Hardware Fault
Orange/Magenta Blinking
Anytime
Device Over Current
Channel Status LED
LED off
Anytime
Channel has voltage and is operating as expected
Red Solid
Anytime
Channel has NO voltage and there is an active fault. Check for tripped or missing circuit breaker
Red Blink
Anytime
Sticky fault on the channel. Check for tripped circuit breaker.
Sticky Fault - an indicator that a fault has occurred that will stay until the indicator has been cleared manually.
Switched Channel LED
LED off
Anytime
Channel has voltage and is operating as expected
Red Solid
Anytime
Channel has NO voltage and there is an active fault. Check for blown or missing fuse
Red Blink
Anytime
Sticky fault on the channel. Check for blown fuse