Power Distribution Hub Specifications

The following tables provide the operating and mechanical specifications for the Power Distribution Hub (PDH).

Main Electrical Specifications

Parameter
Min
Typ
Max
Units

Operating Voltage Range

4.7

12

18

V

Power Input Wire Gauge (Bare Solid)

18

-

6

AWG

Power Input Wire Gauge (Bare Stranded)

18

-

4

AWG

Power Input Bare Wire Strip Length

0.72

0.75

0.79

in

Power Input Wire Gauge (Stranded, with ferrule) †

18

-

6

AWG

Input Voltage Measurement Resolution

-

7.81

-

mV

If using a ferrule, we recommend using square or hex shaped crimps.

CAN Specifications

Parameter
Min
Typ
Max
Units

CAN Termination

-

120

-

Ω

Latching WAGO Connectors

CAN Terminal Wire Gauge (Bare Solid/Stranded)

26

-

14

AWG

CAN Terminal Bare Wire Strip Length

0.31

0.33

0.35

in

CAN Terminal Wire Gauge (Stranded, with ferrule) ††

22

-

18

AWG

Push Button WAGO Connectors

CAN Terminal Wire Gauge (Bare Solid/Stranded)

24

-

18

AWG

CAN Terminal Bare Wire Strip Length

0.33

0.35

0.37

in

CAN Terminal Wire Gauge (Stranded, with ferrule) ††

28

-

20

AWG

As of 01/04/2024, orders made from REV Robotics will ship with the version of the Power Distribution Hub that features Latching WAGO Connectors on the CAN terminal blocks.

††

If using a ferrule, we recommend using square or hex shaped crimps.

High Current Channel Specifications

Parameter
Min
Typ
Max
Units

Fuse/Circuit Breaker Size

-

ATO/ATC

-

-

Supported Fuse/Circuit Breaker Current Rating

-

-

40

A

Channel Current Measurement Range

0

-

127.9

A

Channel Current Measurement Resolution

-

125

-

mA

Supported Wire Gauge (Bare Solid/Stranded)

24

-

8

AWG

Bare Wire Strip Length

0.43

0.5

0.51

in

Supported Wire Gauge (Stranded, with ferrule) †

24

-

10

AWG

If using a ferrule, we recommend using square or hex shaped crimps.

Low Current Channel Specifications

Parameter
Min
Typ
Max
Unit

Fuse/Circuit Breaker Size

-

ATM/APM

-

-

Continuous Output Current

-

-

15

A

Single Channel Peak Output Current †

-

-

20

A

Supported Fuse/Circuit Breaker Current Rating

-

-

15

A

Supported Fuse/Circuit Breaker Current Rating for PH and PCM (See note below)

-

-

20

A

Channel Current Measurement Range

0

-

31.94

A

Channel Current Measurement Resolution

-

62.5

-

mA

Latching WAGO Connectors ††

Supported Wire Gauge (Bare Solid/Stranded)

26

-

14

AWG

Bare Wire Strip Length

0.31

0.33

0.35

in

Supported Wire Gauge (Stranded, with ferrule) ‡

22

-

18

AWG

Push Button WAGO Connectors ††

Supported Wire Gauge (Bare Solid/Stranded)

24

-

18

AWG

Bare Wire Strip Length

0.33

0.35

0.37

in

Supported Wire Gauge (Stranded, with ferrule) ‡

28

-

20

AWG

It is recommended to use a 20A fuse for a single Pneumatic Hub or Pneumatic Control Module connected to any of the three Low-current Channels if using a compressor with a higher peak current draw, such as the CP26 or the Thomas 405ADC38.

Peak current can be sustained for 5 min.

††

As of 01/04/2024, orders made from REV Robotics will ship with the version of the Power Distribution Hub that features Latching WAGO Connectors on the Low Current Channel's WAGO blocks.

If using a ferrule, we recommend using square or hex shaped crimps.

Switched Channel Specifications

Parameter
Min
Typ
Max
Unit

Continuous Output Current †

-

-

15

A

Fuse/Circuit Breaker Size

-

ATM/APM

-

-

Supported Fuse/Circuit Breaker Current Rating †

-

-

15

A

Low Current Channels

0

-

31.94

A

Low Current Channel Resolution

-

62.5

-

mA

Switching Frequency

-

-

10

Hz

Latching WAGO Connectors ††

Supported Wire Gauge (Bare Solid/Stranded)

26

-

14

AWG

Bare Wire Strip Length

0.31

0.33

0.35

in

Supported Wire Gauge (Stranded, with ferrule) ‡

22

-

18

AWG

Push Button WAGO Connectors ††

Supported Wire Gauge (Bare Solid/Stranded)

24

-

18

AWG

Bare Wire Strip Length

0.33

0.35

0.37

in

Supported Wire Gauge (Stranded, with ferrule) ‡

28

-

20

AWG

Continuous current is thermally limited, therefore it depends on environmental and loading factors. Channel may shut itself off automatically if thermal limits are reached

††

As of 01/04/2024, orders made from REV Robotics will ship with the version of the Power Distribution Hub that features Latching WAGO Connectors on the Low Current Channel's WAGO blocks.

If using a ferrule, we recommend using square or hex shaped crimps.

Power Distribution Hub Circuit Breakers

Mechanical Specifications

Parameter
Min
Typ
Max
Units

Body Length

-

8.875

-

in

Body Width

-

4.375

-

in

Body Height

-

1.563

-

in

Weight

-

1.14

-

lbs

Mounting Hole Grid Pitch

-

0.5

-

in

Mounting Screw Size (Clearance)

-

#10

-

-

Case Material

-

ABS

-

-

Mechanical Drawings

Power Distribution Hub mechanical drawings top & front view

Last updated