# Power Distribution Hub Specifications

The following tables provide the operating and mechanical specifications for the Power Distribution Hub (PDH).

{% hint style="danger" %}
DO NOT exceed the maximum electrical specifications. Doing so will cause permanent damage to the Power Distribution Hub and will void the warranty.
{% endhint %}

{% hint style="danger" %}
The Power Distribution Hub's reverse polarity protection DOES NOT protect downstream devices. Verify the correct polarity on all power wires before operation.
{% endhint %}

## Main Electrical Specifications

<table><thead><tr><th width="200">Parameter</th><th align="center">Min</th><th width="145" align="center">Typ</th><th align="center">Max</th><th align="center">Units</th></tr></thead><tbody><tr><td>Operating Voltage Range</td><td align="center">4.7</td><td align="center">12</td><td align="center">18</td><td align="center">V</td></tr><tr><td>Power Input Wire Gauge (Bare Solid)</td><td align="center">18</td><td align="center">-</td><td align="center">6</td><td align="center">AWG</td></tr><tr><td>Power Input Wire Gauge (Bare Stranded)</td><td align="center">18</td><td align="center">-</td><td align="center">4</td><td align="center">AWG</td></tr><tr><td>Power Input Bare Wire Strip Length</td><td align="center">0.72</td><td align="center">0.75</td><td align="center">0.79</td><td align="center">in</td></tr><tr><td>Power Input Wire Gauge (Stranded, with ferrule) †</td><td align="center">18</td><td align="center">-</td><td align="center">6</td><td align="center">AWG</td></tr><tr><td>Input Voltage Measurement Resolution</td><td align="center">-</td><td align="center">7.81</td><td align="center">-</td><td align="center">mV</td></tr></tbody></table>

|  †  | If using a ferrule, we recommend using square or hex shaped crimps. |
| :-: | ------------------------------------------------------------------- |

{% hint style="warning" %}
Make sure to consider the current and safety requirements when choosing a wire gauge for any given application.
{% endhint %}

### CAN Specifications

<table><thead><tr><th width="200">Parameter</th><th align="center">Min</th><th width="145" align="center">Typ</th><th align="center">Max</th><th align="center">Units</th></tr></thead><tbody><tr><td>CAN Termination</td><td align="center">-</td><td align="center">120</td><td align="center">-</td><td align="center">Ω</td></tr><tr><td><strong>Latching WAGO Connectors</strong> †</td><td align="center"></td><td align="center"></td><td align="center"></td><td align="center"></td></tr><tr><td>CAN Terminal Wire Gauge (Bare Solid/Stranded)</td><td align="center">26</td><td align="center">-</td><td align="center">14</td><td align="center">AWG</td></tr><tr><td>CAN Terminal Bare Wire Strip Length</td><td align="center">0.31</td><td align="center">0.33</td><td align="center">0.35</td><td align="center">in</td></tr><tr><td>CAN Terminal Wire Gauge (Stranded, with ferrule) ††</td><td align="center">22</td><td align="center">-</td><td align="center">18</td><td align="center">AWG</td></tr><tr><td><strong>Push Button WAGO Connectors</strong> †</td><td align="center"></td><td align="center"></td><td align="center"></td><td align="center"></td></tr><tr><td>CAN Terminal Wire Gauge (Bare Solid/Stranded)</td><td align="center">24</td><td align="center">-</td><td align="center">18</td><td align="center">AWG</td></tr><tr><td>CAN Terminal Bare Wire Strip Length</td><td align="center">0.33</td><td align="center">0.35</td><td align="center">0.37</td><td align="center">in</td></tr><tr><td>CAN Terminal Wire Gauge (Stranded, with ferrule) ††</td><td align="center">28</td><td align="center">-</td><td align="center">20</td><td align="center">AWG</td></tr></tbody></table>

|  †  | As of 01/04/2024, orders made from REV Robotics will ship with the version of the Power Distribution Hub that features Latching WAGO Connectors on the CAN terminal blocks. |
| :-: | --------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|  †† | If using a ferrule, we recommend using square or hex shaped crimps.                                                                                                         |

### High Current Channel Specifications

<table><thead><tr><th width="207">Parameter</th><th width="158" align="center">Min</th><th align="center">Typ</th><th align="center">Max</th><th align="center">Units</th></tr></thead><tbody><tr><td>Fuse/Circuit Breaker Size</td><td align="center">-</td><td align="center">ATO/ATC</td><td align="center">-</td><td align="center">-</td></tr><tr><td>Supported Fuse/Circuit Breaker Current Rating</td><td align="center">-</td><td align="center">-</td><td align="center">40</td><td align="center">A</td></tr><tr><td>Channel Current Measurement Range</td><td align="center">0</td><td align="center">-</td><td align="center">127.9</td><td align="center">A</td></tr><tr><td>Channel Current Measurement Resolution</td><td align="center">-</td><td align="center">125</td><td align="center">-</td><td align="center">mA</td></tr><tr><td>Supported Wire Gauge (Bare Solid/Stranded)</td><td align="center">24</td><td align="center">-</td><td align="center">8</td><td align="center">AWG</td></tr><tr><td>Bare Wire Strip Length</td><td align="center">0.43</td><td align="center">0.5</td><td align="center">0.51</td><td align="center">in</td></tr><tr><td>Supported Wire Gauge (Stranded, with ferrule) †</td><td align="center">24</td><td align="center">-</td><td align="center">10</td><td align="center">AWG</td></tr></tbody></table>

|  †  | If using a ferrule, we recommend using square or hex shaped crimps. |
| :-: | ------------------------------------------------------------------- |

### Low Current Channel Specifications

<table><thead><tr><th width="228">Parameter</th><th align="center">Min</th><th width="166" align="center">Typ</th><th align="center">Max</th><th align="center">Unit</th></tr></thead><tbody><tr><td>Fuse/Circuit Breaker Size</td><td align="center">-</td><td align="center">ATM/APM</td><td align="center">-</td><td align="center">-</td></tr><tr><td>Continuous Output Current</td><td align="center">-</td><td align="center">-</td><td align="center">15</td><td align="center">A</td></tr><tr><td>Single Channel Peak Output Current †</td><td align="center">-</td><td align="center">-</td><td align="center">20</td><td align="center">A</td></tr><tr><td>Supported Fuse/Circuit Breaker Current Rating</td><td align="center">-</td><td align="center">-</td><td align="center">15</td><td align="center">A</td></tr><tr><td>Supported Fuse/Circuit Breaker Current Rating for PH and PCM (See note below)</td><td align="center">-</td><td align="center">-</td><td align="center">20</td><td align="center">A</td></tr><tr><td>Channel Current Measurement Range </td><td align="center">0</td><td align="center">-</td><td align="center">31.94</td><td align="center">A</td></tr><tr><td>Channel Current Measurement Resolution</td><td align="center">-</td><td align="center">62.5</td><td align="center">-</td><td align="center">mA</td></tr><tr><td><strong>Latching WAGO Connectors</strong> ††</td><td align="center"></td><td align="center"></td><td align="center"></td><td align="center"></td></tr><tr><td>Supported Wire Gauge (Bare Solid/Stranded)</td><td align="center">26</td><td align="center">-</td><td align="center">14</td><td align="center">AWG</td></tr><tr><td>Bare Wire Strip Length</td><td align="center">0.31</td><td align="center">0.33</td><td align="center">0.35</td><td align="center">in</td></tr><tr><td>Supported Wire Gauge (Stranded, with ferrule) ‡</td><td align="center">22</td><td align="center">-</td><td align="center">18</td><td align="center">AWG</td></tr><tr><td><strong>Push Button WAGO Connectors</strong> ††</td><td align="center"></td><td align="center"></td><td align="center"></td><td align="center"></td></tr><tr><td>Supported Wire Gauge (Bare Solid/Stranded)</td><td align="center">24</td><td align="center">-</td><td align="center">18</td><td align="center">AWG</td></tr><tr><td>Bare Wire Strip Length</td><td align="center">0.33</td><td align="center">0.35</td><td align="center">0.37</td><td align="center">in</td></tr><tr><td>Supported Wire Gauge (Stranded, with ferrule) ‡</td><td align="center">28</td><td align="center">-</td><td align="center">20</td><td align="center">AWG</td></tr></tbody></table>

{% hint style="info" %}
It is recommended to use a 20A fuse for a single Pneumatic Hub or Pneumatic Control Module connected to any of the three Low-current Channels if using a compressor with a higher peak current draw, such as the CP26 or the Thomas 405ADC38.
{% endhint %}

|  †  | Peak current can be sustained for 5 min.                                                                                                                                                  |
| :-: | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|  †† | As of 01/04/2024, orders made from REV Robotics will ship with the version of the Power Distribution Hub that features Latching WAGO Connectors on the Low Current Channel's WAGO blocks. |
|  ‡  | If using a ferrule, we recommend using square or hex shaped crimps.                                                                                                                       |

### Switched Channel Specifications

<table><thead><tr><th width="235">Parameter</th><th align="center">Min</th><th width="162" align="center">Typ</th><th align="center">Max</th><th align="center">Unit</th></tr></thead><tbody><tr><td>Continuous Output Current †</td><td align="center">-</td><td align="center">-</td><td align="center">15</td><td align="center">A</td></tr><tr><td>Fuse/Circuit Breaker Size</td><td align="center">-</td><td align="center">ATM/APM</td><td align="center">-</td><td align="center">-</td></tr><tr><td>Supported Fuse/Circuit Breaker Current Rating †</td><td align="center">-</td><td align="center">-</td><td align="center">15</td><td align="center">A</td></tr><tr><td>Low Current Channels </td><td align="center">0</td><td align="center">-</td><td align="center">31.94</td><td align="center">A</td></tr><tr><td>Low Current Channel Resolution </td><td align="center">-</td><td align="center">62.5</td><td align="center">-</td><td align="center">mA</td></tr><tr><td>Switching Frequency </td><td align="center">-</td><td align="center">-</td><td align="center">10</td><td align="center">Hz</td></tr><tr><td><strong>Latching WAGO Connectors</strong> ††</td><td align="center"></td><td align="center"></td><td align="center"></td><td align="center"></td></tr><tr><td>Supported Wire Gauge (Bare Solid/Stranded)</td><td align="center">26</td><td align="center">-</td><td align="center">14</td><td align="center">AWG</td></tr><tr><td>Bare Wire Strip Length</td><td align="center">0.31</td><td align="center">0.33</td><td align="center">0.35</td><td align="center">in</td></tr><tr><td>Supported Wire Gauge (Stranded, with ferrule) ‡</td><td align="center">22</td><td align="center">-</td><td align="center">18</td><td align="center">AWG</td></tr><tr><td><strong>Push Button WAGO Connectors</strong> ††</td><td align="center"></td><td align="center"></td><td align="center"></td><td align="center"></td></tr><tr><td>Supported Wire Gauge (Bare Solid/Stranded)</td><td align="center">24</td><td align="center">-</td><td align="center">18</td><td align="center">AWG</td></tr><tr><td>Bare Wire Strip Length</td><td align="center">0.33</td><td align="center">0.35</td><td align="center">0.37</td><td align="center">in</td></tr><tr><td>Supported Wire Gauge (Stranded, with ferrule) ‡</td><td align="center">28</td><td align="center">-</td><td align="center">20</td><td align="center">AWG</td></tr></tbody></table>

|  †  | Continuous current is thermally limited, therefore it depends on environmental and loading factors. Channel may shut itself off automatically if thermal limits are reached               |
| :-: | ----------------------------------------------------------------------------------------------------------------------------------------------------------------------------------------- |
|  †† | As of 01/04/2024, orders made from REV Robotics will ship with the version of the Power Distribution Hub that features Latching WAGO Connectors on the Low Current Channel's WAGO blocks. |
|  ‡  | If using a ferrule, we recommend using square or hex shaped crimps.                                                                                                                       |

#### Power Distribution Hub Circuit Breakers

{% hint style="info" %}
[Information about the REV ATO Auto-resetting Circuit Breakers has moved to its own page!](https://docs.revrobotics.com/ion-control/pdh/specs/rev-ato-auto-resetting-breakers)
{% endhint %}

## Mechanical Specifications

<table><thead><tr><th width="188">Parameter</th><th align="center">Min</th><th width="155" align="center">Typ</th><th align="center">Max</th><th align="center">Units</th></tr></thead><tbody><tr><td>Body Length</td><td align="center">-</td><td align="center">8.875</td><td align="center">-</td><td align="center">in</td></tr><tr><td>Body Width</td><td align="center">-</td><td align="center">4.375</td><td align="center">-</td><td align="center">in</td></tr><tr><td>Body Height</td><td align="center">-</td><td align="center">1.563</td><td align="center">-</td><td align="center">in</td></tr><tr><td>Weight</td><td align="center">-</td><td align="center">1.14</td><td align="center">-</td><td align="center">lbs</td></tr><tr><td>Mounting Hole Grid Pitch</td><td align="center">-</td><td align="center">0.5</td><td align="center">-</td><td align="center">in</td></tr><tr><td>Mounting Screw Size (Clearance)</td><td align="center">-</td><td align="center">#10</td><td align="center">-</td><td align="center">-</td></tr><tr><td>Case Material</td><td align="center">-</td><td align="center">ABS</td><td align="center">-</td><td align="center">-</td></tr></tbody></table>

{% hint style="danger" %}
DO NOT use thread-locking fluid on the mounting hardware for the REV Power Distribution Hub. Thread-locking fluid will damage the ABS plastic case.
{% endhint %}

### Mechanical Drawings

<figure><img src="https://2227700800-files.gitbook.io/~/files/v0/b/gitbook-x-prod.appspot.com/o/spaces%2FhYImTnzBVrovYdNTo9N8%2Fuploads%2FUVTE1QSrnikcLL8Ugum4%2Fimage.png?alt=media&#x26;token=567c88cf-cae7-4fa5-b58e-54d20f321b58" alt=""><figcaption><p>Power Distribution Hub mechanical drawings top &#x26; front view</p></figcaption></figure>