REV Robotics custom ATO Auto-resetting Breakers are designed to give reliable protection for FRC robot actuators. These custom developed breakers are ATO sized, adhere to SAE Standard J553, and will give consistent performance even after hundreds of breaker trips. A color-coded anodized aluminum case and stamped ratings allow for easy identification and inspection.

REV-11-1860-PK4
10 A
Red
REV-11-1861-PK4
20 A
Yellow
REV-11-1862-PK4
30 A
Green
REV-11-1863-PK4
40 A
Orange
Within the FRC community, there is a common misconception that circuit breakers are designed to trip exactly at a specified current value to protect the devices connected to your Power Distribution Hub. However, a more accurate description would be that circuit breakers are designed to trip at a specific temperature after a set amount of time to protect the electrical system from fire or other electrical hazards.
The current rating on a circuit breaker is the specification of the maximum current at which the circuit breaker is guaranteed not to trip. It is theoretically possible to see a 200% overload for greater than 1 second before it trips. Datasheets for the two most common breakers used with motors in FRC, the 40A REV Robotics ATO Auto-resetting Breakers and the 40A Snap Action MX5 Breakers, show the 40A breakers can see 80A flow through for a short period before they trip.

Operating Voltage Range
4.7
12
18
V
Power Input Wire Gauge (Bare Solid)
18
-
6
AWG
Power Input Wire Gauge (Bare Stranded)
18
-
4
AWG
Power Input Bare Wire Strip Length
0.72
0.75
0.79
in
Power Input Wire Gauge (Stranded, with ferrule) †
18
-
6
AWG
Input Voltage Measurement Resolution
-
7.81
-
mV
†
If using a ferrule, we recommend using square or hex shaped crimps.
CAN Termination
-
†
As of 01/04/2024, orders made from REV Robotics will ship with the version of the Power Distribution Hub that features Latching WAGO Connectors on the CAN terminal blocks.
††
If using a ferrule, we recommend using square or hex shaped crimps.
Fuse/Circuit Breaker Size
-
†
If using a ferrule, we recommend using square or hex shaped crimps.
Fuse/Circuit Breaker Size
†
Peak current can be sustained for 5 min.
††
As of 01/04/2024, orders made from REV Robotics will ship with the version of the Power Distribution Hub that features Latching WAGO Connectors on the Low Current Channel's WAGO blocks.
‡
If using a ferrule, we recommend using square or hex shaped crimps.
Continuous Output Current †
-
†
Continuous current is thermally limited, therefore it depends on environmental and loading factors. Channel may shut itself off automatically if thermal limits are reached
††
As of 01/04/2024, orders made from REV Robotics will ship with the version of the Power Distribution Hub that features Latching WAGO Connectors on the Low Current Channel's WAGO blocks.
‡
If using a ferrule, we recommend using square or hex shaped crimps.
Body Length
-
120
-
Ω
Latching WAGO Connectors †
CAN Terminal Wire Gauge (Bare Solid/Stranded)
26
-
14
AWG
CAN Terminal Bare Wire Strip Length
0.31
0.33
0.35
in
CAN Terminal Wire Gauge (Stranded, with ferrule) ††
22
-
18
AWG
Push Button WAGO Connectors †
CAN Terminal Wire Gauge (Bare Solid/Stranded)
24
-
18
AWG
CAN Terminal Bare Wire Strip Length
0.33
0.35
0.37
in
CAN Terminal Wire Gauge (Stranded, with ferrule) ††
28
-
20
AWG
ATO/ATC
-
-
Supported Fuse/Circuit Breaker Current Rating
-
-
40
A
Channel Current Measurement Range
0
-
127.9
A
Channel Current Measurement Resolution
-
125
-
mA
Supported Wire Gauge (Bare Solid/Stranded)
24
-
8
AWG
Bare Wire Strip Length
0.43
0.5
0.51
in
Supported Wire Gauge (Stranded, with ferrule) †
24
-
10
AWG
-
ATM/APM
-
-
Continuous Output Current
-
-
15
A
Single Channel Peak Output Current †
-
-
20
A
Supported Fuse/Circuit Breaker Current Rating
-
-
15
A
Supported Fuse/Circuit Breaker Current Rating for PH and PCM (See note below)
-
-
20
A
Channel Current Measurement Range
0
-
31.94
A
Channel Current Measurement Resolution
-
62.5
-
mA
Latching WAGO Connectors ††
Supported Wire Gauge (Bare Solid/Stranded)
26
-
14
AWG
Bare Wire Strip Length
0.31
0.33
0.35
in
Supported Wire Gauge (Stranded, with ferrule) ‡
22
-
18
AWG
Push Button WAGO Connectors ††
Supported Wire Gauge (Bare Solid/Stranded)
24
-
18
AWG
Bare Wire Strip Length
0.33
0.35
0.37
in
Supported Wire Gauge (Stranded, with ferrule) ‡
28
-
20
AWG
-
15
A
Fuse/Circuit Breaker Size
-
ATM/APM
-
-
Supported Fuse/Circuit Breaker Current Rating †
-
-
15
A
Low Current Channels
0
-
31.94
A
Low Current Channel Resolution
-
62.5
-
mA
Switching Frequency
-
-
10
Hz
Latching WAGO Connectors ††
Supported Wire Gauge (Bare Solid/Stranded)
26
-
14
AWG
Bare Wire Strip Length
0.31
0.33
0.35
in
Supported Wire Gauge (Stranded, with ferrule) ‡
22
-
18
AWG
Push Button WAGO Connectors ††
Supported Wire Gauge (Bare Solid/Stranded)
24
-
18
AWG
Bare Wire Strip Length
0.33
0.35
0.37
in
Supported Wire Gauge (Stranded, with ferrule) ‡
28
-
20
AWG
8.875
-
in
Body Width
-
4.375
-
in
Body Height
-
1.563
-
in
Weight
-
1.14
-
lbs
Mounting Hole Grid Pitch
-
0.5
-
in
Mounting Screw Size (Clearance)
-
#10
-
-
Case Material
-
ABS
-
-