Status LED Patterns

We're Updating our Documentation! For the most up-to-date information about the Power Distribution Hub and other ION Control System Devices please check out the following new documentation pages:

General Status LED

These led patterns only apply to firmware version 21.1.7 and later

LED StatusLED DescriptionWhenHub Status

Blue Solid

Anytime

Device on but no communication established

Green Solid

Anytime

Main Communication with roboRIO established

Magenta Blinking

Anytime

Keep Alive Timeout

Solid Cyan

Anytime

Secondary Heartbeat (Connected to REV Hardware Client)

Orange/Blue Blinking

Anytime

Low Battery

Orange/Yellow Blinking

Anytime

CAN Fault

Orange/Cyan Blinking

Anytime

Hardware Fault

Orange/Magenta Blinking

Anytime

Device Over Current

Channel Status LED

These led patterns only apply to version 21.1.7 and later

LED StatusLED DescriptionWhenComponent Status

LED off

Anytime

Channel has voltage and is operating as expected

Red Solid

Anytime

Channel has NO voltage and there is an active fault. Check for tripped or missing circuit breaker

Red Blink

Anytime

Sticky fault on the channel. Check for tripped circuit breaker.

Sticky Fault - an indicator there was a fault that will stay until the fault has been cleared manually.

Switched Channel LED

These led patterns only apply to version 21.1.7 and later

LED StatusLED DescriptionWhenComponent Status

LED off

Anytime

Channel has voltage and is operating as expected

Red Solid

Anytime

Channel has NO voltage and there is an active fault. Check for blown or missing fuse

Red Blink

Anytime

Sticky fault on the channel. Check for blown fuse