All pages
Powered by GitBook
1 of 1

Loading...

SPARK Flex Specifications

The following tables provide the operating and mechanical specifications for the SPARK Flex Motor Controller.

DO NOT exceed the maximum electrical specifications. Doing so will cause permanent damage to the SPARK Flex and will void the warranty.

Main Electrical Specifications

Parameter
Min
Typ
Max
Units

PWM Input Specifications

Parameter
Min
Typ
Max
Units

Data Port Specifications

Parameter
Min
Typ
Max
Units

Mechanical Specifications

Parameter
Value and Units

V

Absolute Maximum Supply Voltage

-

-

30

V

Continuous Output Current ††

-

-

60

A

Peak Current (2 second surge)

-

-

100A

A

μs

Full-forward Input Pulse

-

2000

-

μs

Valid Input Pulse Range

500

-

2500

μs

Input Frequency

50

-

200

Hz

Input Timeout ††

-

50

-

ms

Default Input Deadband †††

-

5

-

Hz

Input High Level

0.5

0.7

0.9

V

mA

Digital Input Voltage Range

0

-

5

V

Digital Input High Voltage

1.85

-

-

V

Digital Input Low Voltage

-

-

1.36

V

Analog Input Voltage Range

0

-

Vout

V

Mounting Footprint Narrow Side Width

2 in

Mounting Footprint Rounded Side Diameter

60 mm

Mounting Holes

#10-32 on 2 in bolt circle

Mounting Hole Maximum Depth

0.25 in

Body Length (Not Docked)

28.2mm

Docking Hardware

M3 SHCS x 25mm

Weight (with Wires & Docking Screws)

130g (0.29lb)

Input Voltage (Nominal)

-

12

-

V

Operating Voltage Range †

6

-

†

6 V minimum for 5 V Data Port output. 4.5 V minimum before full brownout.

††

Continuous current duration tested at 3 minutes.

Full-reverse Input Pulse

-

1000

-

μs

Neutral Input Pulse †

-

1500

†

Neutral corresponds to zero output voltage (0 V) and is either braking or coasting depending on the current idle behavior mode.

††

If a valid pulse isn't received within the timeout period, the SPARK Flex will disable its output.

†††

Input deadband is added to each side of the neutral pulse width. Within the deadband, output state is neutral. The deadband value is configurable using the REV Hardware Client or through the CAN interface.

5V Supply Output Voltage (Vout)

V

5V Supply Output Current †

-

-

†

Available output current may be reduced when the SPARK Flex is powered only by USB and not main power.

Power Wire Gauge

12 AWG

Power Wire Length

450 mm (17.72in)

Control Wire Gauge

26 AWG

Control Wire Length

450 mm (17.72in)

Through Bore Diameter

16.5 mm (0.649 in)

24

-

500