REV Robotics HD Hex Motors (REV-41-1291) and the Core Hex Motors (REV-41-1300) come with a magnetic quadrature encoder already installed and an appropriate cable for connecting the encoder output to the REV Robotics Control Hub (REV-31-1595) or Expansion Hub (REV-31-1153). See Table 1 and Table 2 for relevant encoder details.
Core Hex Motor (REV-41-1300) Reduction
72:1
Free Speed (RPM)
125
Cycles per Rotation of the Encoder Shaft
4 (1 Rise of Channel A)
Counts per Rotation of the Output Shaft
288 (72 Rises of Channel A)
The Core Hex Motor uses a 2-pin JST-VH Connector for motor power and a 4-pin JST-PH for sensor feedback from the built-in encoder. For more information on using the cables and connectors included with the Core Hex Motor, see the REV Control System - Cable and Connectors documentation. The image below has the pinout for the motor power and the encoder.
HD Hex Motor Reduction
Bare Motor
40:1
20:1
Free Speed (RPM)
6000
150
300
Cycles per Rotation of the Encoder Shaft
28 (7 Rises of Channel A)
28 (7 Rises of Channel A)
28 (7 Rises of Channel A)
Counts per Rotation of the Output Shaft
28 (7 Rises of Channel A)
1120 (280 Rises of Channel A)
560 (140 Rises of Channel A)
The HD Hex Motor uses a 2-pin JST-VH Connector for motor power and a 4-pin JST-PH for sensor feedback from the built-in encoder. For more information on using the cables and connectors included with the HD Hex Motor, see the REV Control System - Cable and Connectors documentation. The image below has the pinout for the motor power and the encoder.
An encoder is anything (device, software, person) that converts information from one format into another. Some examples of encoding include:
A transducer, like a speaker, which converts an electrical signal into sound waves
Software which encodes an audio file into an mp3 to decrease file size
A stenographer (court reporter) takes courtroom dialog and converts it into a written record
This section is about rotary encoders which are electro-mechanical devices which convert the angular position of a shaft, like on a motor, to an electronic signal. These signals can be fed into a microcontroller, which controls all robot functions, and then used to provide real world data to make better programming decisions.
There are two main types of encoders: absolute and relative.
Absolute encoders return the actual angle of the rotation (e.g. 30°). Absolute encoders maintain position information if the power is removed, and position data is immediately available when power is reapplied with no rotation needed to read the current angle. The relationship between the encoder value and the motor shaft is set when assembled and will always stay the same. Commonly these encoders use a specially printed pattern disk which are read and converted to a known angle. Generally, absolute encoders are easier to use when programming, but they are more complicated to manufacture so are larger, or more expensive.
Relative encoders, which are also referred to as incremental encoders, provide information about the motion of the shaft (e.g. forward at 5 RPM), and only provide data while the shaft is rotating. One way to remember this is that relative encoders return information on the incremental change of the motor output shaft. Relative encoders only provide pulses as the motor turns, and interpreting these pulses into useful information must be done externally. A relative encoder does not know what position it is in at start-up, but it is possible to create a calibration program that must be run at every start-up to obtain reference point to calculate an angle from.
Encoders measure a real world change (shaft rotation) and convert it to an electrical signal. Two common ways to do this are using optical or magnetic feedback:
Optical encoders have a disk with a series of either slots or a reflective pattern around the outside which is attached to the motor shaft. A light shines on or through the disk where the light can pass through or reflect onto a photodiode (device which produces an electric signal when light shines on it). These sensors can be very light and compact, but can be very sensitive to anything that might interfere with the light reaching the photodiode. Finger prints on a reflective disk, or dust from a dirty environment can interfere.
Magnetic encoders have a magnet attached to the shaft of a motor and use Hall effect sensors to detect the changing magnetic field as the shaft rotates. Magnetic encoders are able to operate in harsh or dirty environments.
A 12 pole magnetic quadrature encoder is installed on the rear of both the HD Hex Motor and Core Hex Motor. The output shaft of the motor extends from the rear of the motor case and a multi-pole permanent magnet is attached to the shaft. There are two Hall effect sensors, marked ‘A’ and ‘B’, mounted next to the magnet at 90° to each other. As each of the 12 poles passes across one of the Hall effect sensors, it creates a change in the magnetic field causing the sensor to generate a measurable voltage signal.
Quadrature encoders are a specific type of relative encoder that have four different output states. If the root quad-, means four, but there are only two sensors in this encoder, where does the name come from? The output from the two Hall effect sensors are called “Channel A” and Channel B” respectively; an example of the output is shown below. In a single period (T), defined as the duration of time of one complete cycle in a repeating pattern, the timing diagram has four distinct states (see a, b, c, and d below), hence a quadrature encoder.
The offset from Channel A to Channel B is because the sensors are offset from each other by 90°. As the motor rotates one sensor will see the change before the other. When the motor shaft rotates clockwise (CW), Channel A will lead (the edge will rise before) Channel B. When the motor spins counter clockwise (CCW) Channel A will lag (rise after) Channel B. If there was only one sensor it would still be possible to measure the number of rotations, but not to detect the direction of the motor.
On HD Hex and Core Hex motors Channel A leads Channel B when positive voltage is applied to the M+ terminal. However, there are times when this will not hold true in real life. Different reduction gearboxes, or physically swapping the Channel A and Channel B encoder wires into the controller, can reverse the relationship between the channels. Keep this in mind when programming and troubleshooting your robot.
When the encoder is being read by a microcontroller, the two signals are compared to produce a count up pulse or count down pulse. These pulses are counted as steps forward (CW) or backwards (CCW). Using the specifications for the encoder being used, a count can be converted to degrees. This information can be used to drive a robot arm to a specific angle, or tell a robot to drive a certain distance. Both the Control Hub and Expansion Hub communicate to a microcontroller through the encoder ports.
There is some conflicting terminology difference between encoder suppliers. This document defines one of the most commonly agreed upon set of terms, however be aware that when comparing between encoder specifications from different vendor’s terms may vary in meaning.
Every time the output goes through all four distinct combinations of output signals, it’s called a cycle (see a, b, c, and d below). Encoders have a different cycles-pre-revolution(CPR) based on the number of poles on the magnet used. The CPR is how many cycles are generated for one complete revolution of the encoder shaft.
An example output from one complete rotation of a 14 CPR encoder is shown in in the figure below. A 14 CPR rotation encoder may also be referred to as having 14 rises on channel A. Encoders are mounted to the motor shaft, not the gearbox output shaft, so for a motor with a reduction gearbox attached this is less than one full output shaft rotation.
One reason to use CPR to define an encoder, rather than the commonly used PPR (Pulses per Revolution) is when the encoder signal is decoded by the microcontroller it is possible to do 1x, 2x, or 4x decoding. For 1x decoding the micro controller would only “count” the rising signal on a single channel, while for 4x decoding each rising or falling edge for both channels is measured as a “count.” Although 4x decoding is one of the most common methods, because it’s based on how the electronics decode the signal from the encoder, and not on the encoder hardware itself, it’s not an ideal method of defining the encoder hardware specifications.
If we assume 4x decoding when each cycle is interpreted, the microcontroller can read the four distinct outputs (a, b, c, and d) as individual steps. So for each CPR, the controller can read four counts/ticks. To calculate the number of counts per rotation of the encoder shaft:
The actual cycles per rotation of the output shaft of the motor is depending on the gearbox that’s attached.
This can be calculated into the degrees per count. Assuming no additional reduction is added to the final stage of the motor output (i.e. direct drive) the number of degrees per count is calculated as:
The REV Through Bore Encoder () is specifically designed with the end user in mind, allowing teams to place the sensor in the locations closest to the rotation that they wish to measure. This rotary sensor measures both relative and absolute position through its ABI quadrature output and its absolute position pulse output.
The FTC Control System (Control Hub and Expansion Hub) only supports incremental encoder input through the motor encoder ports at this time. Absolute pulse input is not supported.
Included with the Through Bore Encoder is a 5mm Hex insert and a 4-Pin JST PH to 6-pin JST PH connector. The 6-pin connector is plugged into the Through Bore Encoder with the 4-pin connector plugging into either the Control Hub () and Expansion Hub () Encoder Port. Both the A and B channels of the encoder are used.
When using the 5mm Hex insert, press the insert into the 1/2” Hex hole before attaching to a mechanism. If you are having difficulty pressing the insert into the encoder, try flipping the insert over and press it in. There is a slight taper in the insert, so it is recommended to press the insert with the smaller end first. When removing, it is recommended to push the insert out in the reverse order (larger end first).