We're Updating our Documentation! For the most up-to-date information about the Power Distribution Hub and other ION Control System Devices please check out the following new documentation pages:
These led patterns only apply to firmware version 21.1.7 and later
These led patterns only apply to version 21.1.7 and later
Sticky Fault - an indicator there was a fault that will stay until the fault has been cleared manually.
These led patterns only apply to version 21.1.7 and later
LED Status | LED Description | When | Hub Status |
---|---|---|---|
LED Status | LED Description | When | Component Status |
---|---|---|---|
LED Status | LED Description | When | Component Status |
---|---|---|---|
Blue Solid
Anytime
Device on but no communication established
Green Solid
Anytime
Main Communication with roboRIO established
Magenta Blinking
Anytime
Keep Alive Timeout
Solid Cyan
Anytime
Secondary Heartbeat (Connected to REV Hardware Client)
Orange/Blue Blinking
Anytime
Low Battery
Orange/Yellow Blinking
Anytime
CAN Fault
Orange/Cyan Blinking
Anytime
Hardware Fault
Orange/Magenta Blinking
Anytime
Device Over Current
LED off
Anytime
Channel has voltage and is operating as expected
Red Solid
Anytime
Channel has NO voltage and there is an active fault. Check for tripped or missing circuit breaker
Red Blink
Anytime
Sticky fault on the channel. Check for tripped circuit breaker.
LED off
Anytime
Channel has voltage and is operating as expected
Red Solid
Anytime
Channel has NO voltage and there is an active fault. Check for blown or missing fuse
Red Blink
Anytime
Sticky fault on the channel. Check for blown fuse