Pneumatic Hub Specifications

We're Updating our Documentation! For the most up-to-date information about the Pneumatic Hub and other ION Control System Devices please check out the following new documentation pages:

The following tables provide the operating and mechanical specifications for the Pneumatic Hub.

DO NOT exceed the maximum electrical specifications. Doing so will cause permanent damage to the Pneumatic Hub and will void the warranty.

Main Electrical Specifications

Parameter

Min

Typ

Max

Units

Operating Voltage Range

4.7

12

18

V

Main Power Wire Gauge (Bare Solid/Stranded) †

24

-

16

AWG

Bare Wire Strip Length

0.33

0.35

0.37

in

Main Power Wire Gauge (Stranded, with ferrule) †

24

-

18

AWG

CAN Terminal Wire Gauge (Bare Solid/Stranded)

24

-

18

AWG

CAN Terminal Bare Wire Strip Length

0.33

0.35

0.37

in

CAN Terminal Wire Gauge (Stranded, with ferrule)

24

-

18

AWG

Due to the input current requirements for the Pneumatic Hub, it is recommended to use the maximum wire gauge possible for the Main Power Input.

Make sure to take into consideration current requirements when choosing wire gauge for any given application.

Compressor Output Specifications

Parameter

Min

Typ

Max

Unit

Continuous Compressor Output Current (See note below)

-

-

15

A

Current Measurement Resolution

-

125

-

mA

Wire Gauge (Bare Solid/Stranded)

24

18

16

AWG

Bare Wire Strip Length

0.33

0.35

0.37

in

Wire Gauge (Stranded, with ferrule)

24

18

18

AWG

It is recommended to use a 20A fuse or circuit breaker with the Pneumatic Hub if using a compressor with higher peak current draw, such as the CP26 or the Thomas 405ADC38.

Solenoid Channel Specifications

Parameter

Min

Typ

Max

Unit

Individual Channel Output Current

-

-

200

mA

Total Continuous Output Current

(24V Mode) †

-

-

3.2

A

Total Continuous Output Current (12V Mode) †

-

-

1.5

A

Output Current Measurement Resolution

-

10

-

mA

Wire Gauge (Bare Solid/Stranded)

24

-

20

AWG

Bare Wire Strip Length

0.33

0.35

0.37

in

Total combined current for all solenoid channels.

Digital Pressure Switch Port Specifications

Parameter

Min

Typ

Max

Unit

Input Voltage Range †

0

-

5

V

Input High Level Voltage

-

-

2.31

V

Input Low Level Voltage

0.99

-

-

V

Wire Gauge (Bare Solid/Stranded)

24

-

20

AWG

Bare Wire Strip Length

0.33

0.35

0.37

in

Internally pulled up to 5V.

Analog Pressure Sensor Port Specifications

Parameter

Min

Typ

Max

Unit

Default Pressure Measurement Range †

0

-

200

psi

Corresponding Voltage Measurement to Pressure Range †

0.5

-

5.0

V

Absolute Voltage Measurement Range ‡

0

-

5.0

V

Supply Voltage

-

5

-

V

Supply Current

-

-

95

mA

The Pneumatic Hub assumes a REV Analog Pressure Sensor (REV-11-1107) is connected by default.

The REV Analog Pressure Sensor minimum output voltage is 0.5V. A measurement of 0V triggers a fail safe condition that assumes the sensor has been disconnected.

Mechanical Specifications

Parameter

Min

Typ

Max

Units

Body Length

-

4.375

-

in

Body Width

-

1.875

-

in

Body Height

-

0.750

-

in

Weight

-

0.1625

-

lbs

Mounting Hole Grid Pitch

-

0.5

-

in

Mounting Screw Size (Clearance)

-

#10

-

-

Case Material

-

ABS

-

-

DO NOT use thread-locking fluid on the mounting hardware for the REV Pneumatic Hub. Thread-locking fluid will damage the ABS plastic case.

Mechanical Drawings

Last updated