LogoLogo
REVLib Docs
  • REV ION Control System
  • Quick Links
  • Frequently Asked Questions
  • Power Distribution Hub
    • Power Distribution Hub Overview
    • Power Distribution Hub Specifications
    • Getting Started with the Power Distribution Hub
      • Wiring the Power Distribution Hub
    • Power Distribution Hub Status LED Patterns
    • Power Distribution Hub Troubleshooting
    • Power Distribution Hub Firmware Changelog
  • Pneumatic Hub
    • Pneumatic Hub Overview
    • Pneumatic Hub Specifications
    • Getting Started with the Pneumatic Hub
      • Wiring the Pneumatic Hub
    • Pneumatic Hub Status LED Patterns
    • Pneumatic Hub Troubleshooting
    • Pneumatic Hub Firmware Changelog
  • Radio Power Module
    • Radio Power Module Overview
    • Radio Power Module Specifications
    • Getting Started with the Radio Power Module
    • RPM Compatibility with the new FRC Radio
  • Mini Power Module
    • Mini Power Module Overview
    • Mini Power Module Specifications
    • Mini Power Module Status LED Patterns
  • Sensors
    • 2m Distance Sensor
    • Color Sensor V3
    • Magnetic Limit Switch
    • Potentiometer
    • Through Bore Encoder
    • Touch Sensor
  • Accessories
    • Blinkin LED Driver
    • Digital LED Indicator
    • Servo Power Module
    • POE Injector Cable
    • JST PH 6-Pin Breakout Board
    • JST PH 6-pin Joiner Board
  • Software Resources
    • REV Hardware Client Documentation
    • REVLib
Powered by GitBook
On this page
  • Main Electrical Specifications
  • Mechanical Specifications
  • Mechanical Drawings

Was this helpful?

Export as PDF
  1. Radio Power Module

Radio Power Module Specifications

The following tables provide the operating and mechanical specifications for the Radio Power Module.

DO NOT exceed the maximum electrical specifications. Doing so will cause permanent damage to the Radio Power Module and will void the warranty.

DO NOT reverse the 12V power input polarity. Doing so will cause permanent damage to the REV Radio Power Module and will void the warranty.

Main Electrical Specifications

Parameters
Min
Typ
Max
Unit

Operating Voltage Range

4.7

12

18

V

Continuous Output Current

-

-

1

A

Latching WAGO Connectors †

Power Input Wire Gauge (Bare Solid/Stranded)

26

-

14

AWG

Bare Wire Strip Length

0.31

0.33

0.35

in

Power Input Wire Gauge (Stranded, with ferrule)

24

-

18

AWG

Push Button WAGO Connectors †

Power Input Wire Gauge (Bare Solid/Stranded)

24

-

16

AWG

Bare Wire Strip Length

0.33

0.35

0.37

in

Power Input Wire Gauge (Stranded, with ferrule)

24

-

18

AWG

†

As of 01/04/2024, orders made from REV Robotics will ship with the version of the Radio Power Module that features Latching WAGO Connectors.

Make sure to consider the current and safety requirements when choosing a wire gauge for any given application.

DO NOT connect the roboRIO to the WiFi Radio Ethernet port. Doing so can cause permanent damage to the roboRIO.

Mechanical Specifications

Parameter
Min
Typ
Max
Units

Body Length

-

3.375

-

in

Body Width

-

1.250

-

in

Body Height

-

0.875

-

in

Weight

-

0.09

-

lbs

Mounting Hole Grid Pitch

-

0.5

-

in

Mounting Screw Size (Clearance)

-

#10

-

-

Case Material

-

ABS

-

-

DO NOT use thread-locking fluid on the mounting hardware for the REV Radio Power Module. Thread-locking fluid will damage the ABS plastic case.

Mechanical Drawings

PreviousRadio Power Module OverviewNextGetting Started with the Radio Power Module

Last updated 10 months ago

Was this helpful?

Radio Power Module Mechanical Drawing Top and Front View